Water and Its Physicochemical Properties: Expert Aquarium and Aquariology Manual
Mineralization and hardness of inland waters
The hardness of freshwater (inland water) partly reflects the mineralization of aquarium water through GH (general hardness) and KH (temporary hardness or buffering capacity). Measuring these parameters is often critical for aquarium inhabitants, particularly sensitive species.
Good to know: the term "inland water" (as opposed to "seawater") is preferred here to avoid any confusion between "fresh/soft water" and "hard water" regarding the total mineralization of waters commonly grouped under the term "freshwater." This distinction will be used throughout the aquariology guide for expert aquarists.
A tropical river carries inland freshwater:
Inland water can vary in color, and above all in its chemical composition.
What are inland waters?
Inland waters differ from marine waters by their low level of mineralization:
- 35 g of dissolved salts per liter on average for seawater.
- Between 0 and 0.5 g of dissolved salts per liter for inland waters.
Brackish waters, with intermediate yet highly variable mineralization, support a specialized fauna.
While seawater is relatively uniform in composition, the same cannot be said for inland waters. They exhibit extreme variability that must be accounted for when stocking an aquarium. Mineralization and physicochemical water composition rank alongside temperature among the primary ecological factors shaping life in a body of water, in addition to lighting, which plays a vital role for aquatic plants.
Because all inland waters originate directly or indirectly from completely demineralized rainwater, their chemical makeup varies widely from place to place depending on the geological formations they percolate through to reach a spring or flow over along the surface.
Direct consequence: spring water or municipal tap water used to fill aquariums can have a composition very different from the native biotope of the inhabitants you keep. Despite the relatively strong adaptability of most common species, you should keep in mind that a mismatch from the outset can hinder the long-term survival and health of a given ornamental fish.
To illustrate how critical water mineralization can be, consider fish toxicity tests standardized under the French Standardization Association (AFNOR). For results to be comparable from one laboratory to another, the test water must have identical properties—which is why standardized reconstituted "soft" water is used for these tests!
The biology of the salmon offers another remarkable example of inland water variability. How does it locate the exact river where it hatched? Through chemical sensing! Just as an oenologist recognizes a fine vintage wine, a salmon recognizes "by taste" the water of its birth stream!
Knowing the mineralization of the water used to fill and perform water changes in our aquariums is therefore essential.
Measuring water hardness
Relatively simple methods exist to measure what we call water hardness. In most towns, you can also obtain the physicochemical profile of municipal tap water directly from your local water utility or town hall. For spring water (bearing in mind that potable springs are relatively uncommon), standard aquarium test kits work well to evaluate water quality.
Simple testing kits are readily available in aquarium stores.
This makes it easy to compare your water's hardness with that of other regions or with values cited in aquarium literature for a given fish species' biotope.
More broadly, any physicochemical water analysis should specify the testing method used so that results remain comparable. Note also that upon boiling, a portion of the dissolved calcium precipitates out—the same limescale buildup seen in a kettle or around an aquarium heater element under the effect of heat.
Measuring water hardness again after boiling reveals that it drops to varying degrees. These observations define three types of hardness:
- Temporary hardness (removed by boiling)
- Permanent hardness (remains after boiling),
- Total hardness (temporary hardness + permanent hardness).
These straightforward concepts play an important role in stabilizing the environment where fish and aquatic plants live. Temporary hardness in particular acts as a buffer that prevents chemical reactions from shifting water parameters too abruptly.
Practical consequences: which water should you choose?
Once you know the total hardness of your available water, it can be classified as follows (values in French degrees, divide by 1.78 to obtain German dGH):
- Very soft: 0 to 5 °
- Soft: 6 to 10 °
- Moderately hard: 11 to 15 °
- Hard: 16 to 30 °
- Very hard: above 30 °
It is best to select your aquarium livestock accordingly.
In principle, water exceeding 30 ° hardness is considered unsuitable for regular tap consumption unless it possesses specific properties found in mineral waters, as is the case for many bottled drinking waters. Volvic bottled water (around 5 ° hardness), by contrast, is soft to very soft and therefore ideal for blending down overly hard tap water or spring water. Other methods are also available to soften your water.
The first is collecting rainwater in a plastic cistern (never metal), provided you live in an area free from atmospheric pollution—otherwise it is best avoided (and over the years, unpolluted rainwater has become rare outside mountain regions).
The second is using reverse osmosis (RO) water or deionized water produced by ion-exchange resin filters.
Warning: never use household ion-exchange "water softeners" regenerated with table salt, as they simply swap calcium for sodium and will gradually turn your aquarium water into brine!
Very soft, RO, or demineralized water must never be stored or piped through metal or rubber containers or tubing—always use food-grade plastic. Chemically pure water aggressively leaches soluble compounds from materials it contacts, including toxic metal salts.
Most inland aquatic species, both fish and plants, prefer or adapt well to soft to moderately hard water. Some require very soft water, especially for breeding, whereas others (livebearers in particular) thrive in hard to very hard water. Moreover, at equal total hardness, major chemical differences often exist between European waters—typically dominated by calcium hardness (from limestone)—and African Rift Lake waters, where hardness is largely magnesium-based (from magnesium).
Before planting and stocking, always check your chosen species' requirements or tolerance regarding your local water. If it is too hard, soften it using one of the methods above. If it is too soft, placing a calcareous rock in the tank as hardscape will gently raise hardness; some aquarists also add 1 to 2% seawater (the upper limit to avoid harming plants).
Do not use boiled water: artificially softened by driving off temporary (carbonate) hardness, it has lost properties essential to aquarium stability.
Note also that total hardness is expressed in different units depending on the country:
- The French degree (°fH) equals 10 mg/L of calcium carbonate (4 mg/L of calcium).
- The German degree (°dGH) equals 10 mg/L of calcium oxide (quicklime).
- The English degree (°e) equals 1 grain of calcium carbonate per imperial gallon.
Resistivity and Conductivity
The electrical conductivity of water is defined as the conductance of a water column between two metal electrodes each measuring 1 cm2 in area and spaced 1 cm apart.
Measuring a water's resistivity—or its reciprocal, conductivity—indicates its overall mineralization. This measurement is taken with a conductivity meter: the current flowing between the electrodes is proportional to conductance, which itself varies with temperature. Because readings are temperature-dependent, the instrument must include manual or automatic temperature compensation.
Resistivity is expressed in ohm-centimeters (Ω/cm), while conductivity is expressed in siemens per meter (S/m) or microsiemens per centimeter (µS/cm).
However, conductivity readings cannot yield exact concentrations of individual mineral salts, nor establish an exact conversion to hardness. Furthermore, standard conductivity meters are inapplicable in seawater due to its extremely high mineralization!
Conductivity can nevertheless provide a rough estimate of hardness in freshwater, as 1 °TH corresponds to roughly 15 µS/cm at 20 °C. A disproportionately higher conductivity points to the presence of dissolved mineral salts other than calcium and magnesium.
Salinity (recommended average value 1025)
Salinity indicates, in grams per liter, the mass of dissolved salts in one liter of water, expressed by convention as grams per liter of sodium chloride (S‰).
A salinometer equipped with automatic or manual temperature compensation is typically used for these measurements. Unlike a standard freshwater conductivity meter, this instrument is highly valuable in marine aquariums, offering instant readings of dissolved salt content so you can match salinity to the geographic origin of your livestock.
Seawater contains an average of 35 g/L of various salts, expressed as S = 40‰ (36–38‰ in the Mediterranean, 40‰ in the Red Sea and other semi-enclosed seas).
Because the specific gravity of water depends on salinity, marine aquarists commonly use a hydrometer to monitor seawater, targeting an average specific gravity around 1025.
Note that marine species commonly kept in aquariums tolerate substantial shifts in salinity or specific gravity (1018 to 1040) without harm, provided changes occur gradually. Sudden salinity drops are sometimes used therapeutically against certain ectoparasites whose tissues withstand osmotic shock less effectively than fish.
Note: Conductivity meters and salinometers are often combined into a single dual-range instrument controlled by a selector switch. Always ensure temperature compensation is accounted for when reading results.